NCIE-SAN Certification Preparation (NS0-520): Part 1 - Practice Tests and Answers

My NCIE-SAN expired a while back (but my NCDA is active), and I have some time, so time to study for the NS0-520.

Below I present some official practices tests and answers (maybe a little explanation too.) But first some notes.

NSO-520: NetApp Certified Implementation Engineer - SAN Specialist, ONTAP

The official certification page is via this link:

https://www.netapp.com/support-and-training/netapp-learning-services/certifications/implementation-engineer-san-specialist/

Under the Section "Prepare for your exam" there are some "Recommended Training and Resources." Personally, I would change the order of those to:

  1. Practice Test for NS0-520
  2. View Exam Topics
  3. ONTAP SAN Fundamentals (WBT)
  4. SAN Administration (ILT)
  5. SAN Implementation (ILT)
  6. Register for NS0-520
Everyone is busy, so best to try the practice test first. If you know enough you can go straight to the exam. Otherwise view the exam topics and study as required.

Practice Questions and Answers (28)

Q1: Active IQ OneCollect collects data from which two solutions?

A: Cloud Volumes Service
B: FlexPod
C: SnapCenter
D: ONTAP AI

Answer: B & C

Q2: You are designing a solution to support an application that requires an FC-attached storage system with symmetric active-active multipathing. Which NetApp product satisfies this requirement?

A: NetApp SolidFire
B: NetApp AFF
C: NetApp AFF All SAN Array
D: NetApp HCI

Answer: C

Q3: A customer has an existing large aging FC SAN environment that is reaching end of support. The environment consists of several large database servers with attached LUNs. You propose using an AFF A250, but you need to gather all end-to-end information in the current environment. In this scenario, which resource contains the information?

A: SAN Health Check
B: Active IQ OneCollect
C: Hardware Universe (HWU)
D: Interoperability Matrix Tool (IMT)

Answer: B

Q4: Which two statements are correct about the AFF All SAN Array (ASA)?

A: AFF ASA supports near-instantaneous unplanned failovers and givebacks
B: AFF ASA supports an active path to any LUN that is hosted on either controller in the HA-pair.
C: AFF ASA supports multiple protocols including NFS, FC, and NVMe over Fibre Channel
D: AFF ASA provides active-optimized and active-non-optimized to any LUN hosted on either controller in the HA pair.

Answer: A & B

Q5: Referring to the cabling layout shown in the exhibit, what is the minimum number of zones required to maintain qualified multipathing from the host to the ONTAP cluster?


A: 1
B: 2
C: 4
D: 8

Answer: B (each switch needs minimum one zone)

Q6: A customer's application is in need of ONTAP 9.8 symmetric active-active paths for iSCSI LUNs. In this secenario, what should be used to help the customer?

A: A 8-node NetApp AFF All SAN Array
B: A 8-node NetApp AFF
C: A 2-node NetApp AFF All SAN Array
D: A 2-node NetApp AFF

Answer: C (needs to be ASA for symmetric active-active paths, and these symmetric active-active paths are only across the 2 nodes of a HA-pair)

Q7: You have an SVM with FC access and you want to create a LUN. When creating the LUN, which statement is true?

A: The volume containing the LUN should be a FlexGroup volume
B: The volume containing the LUN should be a FlexVol volume
C: The volume containing the LUN should be a traditional volume
D: You should map the LUN to multiple portsets

Answer: B

Q8: An administrator is configuring the iSCSI protocol on a newly deployed ONTAP 9.8 cluster. In this scenario, which two actions would accomplish this task?

A: Identify the target WWPN
B: Configure an igroup for the host access
C: Configure SLM
D: Install a license

Answer: B & D

Q9: An administrator is deploying a MetroClsuter configuration with Broadcom switches. Following the successful execution of the reference configuration file (RCF), which two actions does the administrator need to perform on the MetroCluster switches?

A: Configure the zoning.
B: Configure the time zone attribute
C: Configure the Inter-Switch-Link (ISL) distance attribute
D: Configure the switch-port attribute

Answer: B & C

Q10: You are asked to troubleshoot performance issues in a customer's SAN environment. You confirm multipathing is fuctioning properly and there are no port errors. After reviewing the NetApp SAN and hosts for best prectices, you have narrowed down the issues to the fabric switches. In this scenario, which component should be verified?

A: FLOGI database
B: F_Port config
C: BB_Credit counters
D: loss sig counters

Answer: C

Q11: You have a NetApp FAS8700 hybrid flash system with NetApp ONTAP 9.7 software. You want to expand the front-end FC I/O capabilities, but you do not know which target adapters are supported. In this scenario, which NetApp resource do you use to verify which adapters are supported?

A: Interoperability Matrix Tool (IMT)
B: Hardware Universe (HWU)
C: Upgrade Advisor
D: OneCollect tool

Answer: B (HWU when you want to know about target adapters supported in a NetApp)

Q12: Which NetApp resource do you use to verify that NetApp supports a specific SAN configuration?

A: Active IQ
B: Hardware Universe (HWU)
C: Interoperability Matrix Tool (IMT)
D: SAN Configuration Guide

Answer: C (IMT when you want to verify interoperability of components in a SAN configuration) 

Q13: An administrator wants to design an NVMe solution to connect Linux hosts to a NetApp ONTAP cluster. The proposed solution uses two Cisco MDS 9396T switches for each fabric in a top-of-rack design. In this statement, which statement is true?

A: A middle-of-rack design is required.
B: N_Port ID virtualization (NPIV) must be enabled on all switches.
C: Asymmetric namespace access (ANA) requires ONTAP 9.4 or later.
D: NVMe solutions require heterogeneous multiple switch fabrics.

Answer: B (A & D are obviously false. C is wrong because ANA requires ONTAP 9.5 or later.)

Q14: Which two features does asymmetric namespace access (ANA) support?

A: Path management
B: Multipathing
C: LUN hosting
D: LUN masking

Answer: A & B

Q15: On a NetApp AFF A800 all-flash storage system, which NetApp resource identifies the number of available, supported slots for unified target adapater 2 (UTA2) adapters?

A: OneCollect tool
B: Interoperability Matrix Tool (IMT)
C: Active IQ
D: Hardware Universe (HWU)

Answer: D

Q16: A customer's NetApp infrastructure nears end-of-life. The customer wants to inventory their NetApp cluster. The proposed technical refresh must satisfy the customer's growing demand for data. In this scenario, which two NetApp resources do you use?

A: Active IQ Config Advisor
B: OneCollect tool
C: Active IQ Digital Advisor
D: Upgrade Advisor

Answer: B & C

Q17: Which features of NetApp ONTAP software achieves automatic host-side space management with SCSI T10 thin-provisioned LUNs?

A: space reservation
B: space allocation
C: volume auto-grow
D: fractional reserve

Answer: B

Q18: Which NVMe OS multipathing stack does VMware ESXi support?

A: NMP
B: Microsoft Multipath I/O (MPIO)
C: PVlinks
D: Device Mapper Multipathing (DM-Multipath)

Answer: A

Q19: Which two configurations does NetApp ONTAP 9.7 software support?

A: Multiple NVMe LIFs in the same SVM.
B: An NVMe LIF associated with an FC direct-connect port
C: An NVMe LIF and an FC LIF in the same SVM
D: An NVMe LIF and an FC LIF associated with the same port

Answer: A & D

Q20: On a NetApp ONTAP 9.8 cluster, you need to set up the Onboard Key Manager with hardware-based security and volume encryption. Which two licenses are required in this situation?

A: Trusted Platform Module (TPM)
B: Volume Encryption (VE)
C: Full disk encryption (FDE)
D: Remote Support Agent (RSA)

Answer: A & B

Q21: You want to connect a NetApp AFF A700 all-flash storage system to a 32Gb FC switch. The ports need to connect at a speed of 32Gnps. In this scenario, which statement is correct?

A: The AFF A700 includes FC ports natively on the controller.
B: You need to purchase a two-port or four-port unified I/O module that enables FC and Ethernet connectivity.
C: You need to purchase a two-port or four-port FC I/O module.
D: The AFF A700 includes an extra FC I/O module that is already populated in each controller.

Answer: C

Q22: An administrator has a NetApp AFF A220 all-flash storage system with two DS224C drive shelves. The administrator wants to validate that the shelf cabling is correct. Which NetApp resource should they use to accomplish this task?

A: Interoperability Matrix Tool (IMT)
B: Active IQ Config Advisor
C: OneCollect Tool
D: Active IQ Unified Manager

Answer: B

Q23: A customer has multiple host applications that required FC block storage. You need to gather and validate the customer's requirements for a supported NetApp solution. Which two NetApp resources do you use to accomplish this task?

A: Active IQ Config Advisor
B: Interoperability Matrix Tool (IMT)
C: OneCollect Tool
D: Hardware Universe (HWU)

Answer: B & C

Q24: A customer has an 8-node cluster that consists of six NetApp FAS2650 nodes and two NetApp FAS2554 nodes. The customer wants to expand the cluster by adding two NetApp AFF A220 nodes. Which NetApp resource determines whether NetApp supports this configuration?

A: Hardware Universe (HWU)
B: Interoperability Matrix Tool (IMT)
C: Active IQ Config Advisor
D: OneCollect tool

Answer: A

Q25: You want to expand a NetApp SAN-only ONTAP 9.7 cluster that consists of eight NetApp AFF A700 nodes. What is the maximum number of AFF A700 nodes that you can add?

A: 0
B: 2
C: 4
D: 8

Answer: C

Q26: A customer has a switchless two-node NetApp FAS2750 cluster. The customer wants to add two NetApp AFF A400 nodes to the cluster. In addition to the AFF A400 cluster nodes, what else does the customer need to expand the cluster?

A: Additional DS224C shelves
B: Cluster switches
C: Additional manaagement switches
D: An upgrade to ONTAP 9.8

Answer: B

Q27: Which two commands for data mobility operations do you use to seamlessly move data in NetApp ONTAP software?

A: vol move
B: network interface migrate
C: lun move
D: lun map

Answer: A & C

Q28: You configure NVMe and FC on a 2-node NetApp AFF A800 ONTAP 9.7 cluster. You also configure NVMe and FC on Cisco FC network switches. In this scenario, which cluster configuration does NetApp support?

A: A LIF with FC-NVMe and FCP data protocols.
B: An SVM with both FC-NVMe and FCP allowed protocols.
C: An AFF A800 node host bus adapter (HBA) with both NVMe/FC and FC on the same port.
D: A volume with both LUNs and namespaces

Answer: C

Comments